温度控制电池短路试验箱电池大电流短路机设计符合标准;2.根据短路试验要求,短路电流必须小于5 mΩ才能达到最大电流;3.对于短路系统,电气系统必须进行承载能力设计;因此,贝尔团队选用全铜端子的工业直流磁触点,内部铜电流传导,内置主动珠轴流风机冷却,确保测试系统更安全,降低试验机功耗,使测试数据准确。4.试验判断标准:蓄电池短路试验后无火焰或爆炸。性能参数:BE-8102结构一体结构,门采用防爆锁和防爆链Max。 short-circuit current1000A Internal Resistance 80±20 mΩ (Load-current 400A) Remote Control Available Distance 7 meters without solid barrier Controlling Mode PLC touch type (7 inch) + remote control Mechanical Life 300 thousand times Electric Life Resistive load 50,000 times Temperature Range Normal temperature to 80°C or 0-80°C (Optional) Temperature Fluctuation ±1℃ Temperature Deviation ±2℃ Inner Chamber Dimension W600 X D500 X H600mm Inner Chamber Material 1.0mm thickness 304# stainless steel External Chamber Dimension W940XD780XH1620 mm External Chamber Material Cold-rolled sheet paint with1.5mm thickness, total thickness together with inner chamber is 100mm)